If the 13a fcu was there to protect the reduced size of the condutors and cpc then there would be a requirement to use a fcu for ANY spurs, single. Twin and earth 2. Sliding Wardrobe Doors Track Set. Order British General Nexus Metal 13A Switched Fused Spur Brushed Steel at Screwfix. Raised Slim Profile. FCU: Switches & Sockets Profile Type: Raised Rounded: Terminal Capacity: Terminals accept 3 x 2. screwguy, Mar 31, 2005. Pay your way. An alternative which was suggested was to replace the wall socket with a switch with a flex outlet and wire the multiway into it, via the front flex. Deposits in Sunstate Federal Credit Union are insured by NCUA. Home Forums > Screwfix Community Forum > Electricians' Talk > Switch FCU (LED not working) Discussion in 'Electricians' Talk' started by sp383, Nov 13, 2018. The FCU will have a removable bit of plastic for a flex to go into. woodbutcherbower, Dec 2, 2021. Click & Collect. An FCU is not switchgear. Transfers. com. Buy any 10+ Save 10% - View Offer. USF FCU offers helpful services like convenience pay, loan skip-a-pay. 49 Inc Vat. Home Forums > Screwfix Community Forum > Electricians' Talk > Ip66 FCU. load. Our advanced system is protected by state-of-the-art security and includes all the latest conveniences in online banking. FREE next day delivery available, free collection in 1 minute. com. FREE next day delivery available, free collection in 1 minute. unphased Screwfix Select. Google Pay and Apple Pay are accepted in store. Skip to content. With RCD. Membership required. Easily secure a wide range of applications in place. 4. Click on the gear wheel. PayPal accepted online. Triton Thermostatic Mixer Shower Valve 266 x 60 x 50mm, at Screwfix. Terminals accept 3 x 2. Was to see if any one in the forum could see a problem. Raised Rounded Profile. Free returns. The FCU is pointless. Wood Products. So it depends on various things really. Anyway,,,,,,,, as far as I know (I’m diy) the regs state that you can have a socket in a bathroom as long as it’s 3m away from a bath and/or shower and water jets. Comlec Screwfix Select. 2692mm. 800. You can take one double or one single socket on one spur. madhatter1uk Screwfix Select. With Flex Outlet. The UK’s leading retailer of trade tools and hardware. As the title says, I have an outdoor socket which is connected to a 13amp FCU on an RCD ring main. Thus is there such an device to swap the FCU for a timer version so that the electrical heater will only come on for say an hour? Appreciate any other setup that I could have to help? (Change / education of wife not really an acceptable solution!) Regards. Terminal Capacity. The spur is not normally accessible hence the switched FCU. My plan (which I assume to be ok) is to chop off the plug, remove the old socket and use the existing cable to wire into an unswitched fcu. Angled In-Line Terminals with Backed-Out Captive Screws. FREE next day delivery available, free collection in 1 minute. Flexible 13A fuse unit. £ 1. I currently have an FCU supplying ONE outside PIR security light. The problem is when I switch on the sheds fcu it trips the rcbo at the CU, however when i reset it all is fine and I can use the shed, it also trips when I switch off the sheds fcu. Terminal Capacity. US Toll-Free: 1-800-247-5626. Again check no power to alarm panel. That is why the fcu has a 13A fuse. Easily review your checking and savings accounts, set up money transfers, schedule automatic payments, manage personal finances, and more. com. Screwfix customers rate this product 4. And as in te original query - a plug on a cooker hood. Assemble with other products into a modular front plate to create a grid. com. My plan was to use 2. I've just bought this FCU, but confused if it is Single or Double pole? As the reviews/Q&A show that some people have recieved a Single pole and others a Double pole unit. com. 4/5. Over 40,000 products. Online, mobile and phone banking are available 24/7. 5mm t+e cable to a strip light. KC DIY New Member. com. Click & Collect. 60%>5. What is common practice is a FCU mounted 150-200mm from the side of the finished chimney with a 1mm T/E buried in the wall from the FCU (fusedd at 3A) at 90 degree's which then exits the plaster dead centre inside the chimney location which can then be junctioned box'd on to the flying lead inside the. The fused spur switch light came on fine but as soon as I plugged in the washing. 5mm² cables. Home Tags > fcu. Nearest supply was a switched FCU (@3Amp) wired in downstairs ring main for cooker hood. m. 3/5. PayPal accepted online. Pay your way. 25 gallon Tank with lid. 204 Accessories to BS 1363 may be supplied through a ring final circuit, with or without unfused spurs, protected by a 30 A or 32 A protective device complying with BS 88 series, BS 3036, BS EN 60898, BS EN 60947-2 or BS EN 61009-1 (RCBO). 80%>6. At the Screwfix online store you'll find all manner of DIY products, discounts and best-ever prices. It is not installed to 17th edition (or 16th edition) regulations. 22 to 2 x 2. 842. We identify you as the true “owner” of your account. there’s no need. With Flex Outlet. i dont want to cut another hole in the wall and move it along. You made that up. Learn how you can enjoy lower fees, higher dividends, free financial education, and more. Screwfix customers rate this product 4. com. Take a spur off a socket above the worktop as a feed to the new single socket. The switched FCU fused at 3 or 5A feeds the lights. joinerjohn1 Screwfix Select. 7/5. Buy online & collect in hundreds of stores in as little as 1 minute! Free returns. Installing spurs on a new circuit is sloppy. Hi guys got 3 klima 5m 750 watt heating Matt's in a kitchen. I've heard. Space to mount the new socket and FCU is pretty tight and it'll be very visible from the patio. 6/5. I know that if on a fcu, you can spur from a spur but I can’t draw more than 13 amps. You can move money between your accounts with just a few clicks, including loan payments! For one time or recurring transfers you have the option to schedule or move right away. com. unphased Screwfix Select. An assembly of main and auxiliary switching equipment for operation, regulation, protection or other control of an electrical installation. Discussion in ' Electricians' Talk ' started by DoItYoung, Feb 9, 2021 . Screwfix customers rate this product 4. People do do that with washing machines then put a switch above the worktop. Terminals accept 3 x 2. - - - - Call 24/7 on: 03330 112 112 Call 24/7: 03330 112 112 Shop by. £15. However, from a practical point of view you would change the present fcu to an unswitched 13A spur, then connect two 3A fcus one serving each of the boiler and the pump. Supplied with four screw cap covers for a sleek profile finish. British General 900 Series 13A Unswitched Passive Fused Spur White (8250P) (57) compare. You can't use a FCU without attaching something to the load. #5. unphased Screwfix Select. woodbutcherbower, Dec 2, 2021. Apple Pay accepted in store. DIYDave. Discussion in 'Electricians' Talk' started by paaulyb, Oct 11, 2006. Buy 45 A Fused Spurs at Screwfix. Greetings, my wife would like a double gang socket in the potting shed for her heat mat for the plants and other very low voltage items with no lighting required - just a double gang socket. The socket has no specific use, perhaps hoover etc. Am adding a 13A FCU/timer indoors to control it, so question is whether to put this before or after the 20A isolator? NB indoor and outdoor interconnects are DC 24V only so so intermediatory. Was taught that way must be 30 years ago. Select. ? thanks for any input / help lads. Spur off socket to unswitched FCU From unswitched FCU to a switched FCU (needed for functional switching of fly zapper) The load side of SFCU going to the fly zapper and from feed side of SFCU to another SFCU to power outside light. Order online at Screwfix. com. All of the lines and rectangles in GREEN are my proposed wiring. 5mm², 2 x 4mm² or 1 x 6mm² cables. 48 Inc Vat. Flex Outlet. I have ordered 50m of 10mm swa cable. 2. 5 from the load side of this spur with a 13 amp fuse into the supply side of a spur in the right hand side of the box. Your light now comes off the load side of this with a 3 amp fuse and the two new sockets come. Drill holes through the back of it through the wall. Terminals accept 3 x 2. However, this is frowned upon as poor practice. Screwed Faceplate. 120-136mm x 100-115mm. Order online at Screwfix. Select “Make a Loan Payment” from the main menu. Discussion in ' Electricians' Talk ' started by ScubaCollie, Jul 2, 2021 . comes with a plug, so it can be disconnected. 1, 1957. We'll that's what I've always used when I've done outside pond jobs. MGW, Nov 6, 2022. com. We offer safe deposit boxes in a variety of sizes to keep your important papers and valuables safe. Personally I would use 2. Screwfix customers rate this product 4. Home Forums > Screwfix Community Forum > Electricians' Talk > FCU location on cooker hood install Discussion in ' Electricians' Talk ' started by BodgeTheBuilder , Jun 14, 2020 . 0mm cables, therefore 2 x 2. Page 3 of 3 < Prev 1. com. Screwfix Community Forum. com. 10x10 — $90 / year. Pay your way. At the moment FCU is wired to the existing single. Who has a socket fitted 2m off the ground? A proper kitchen install will have an FCU there not a socket. That's two cables on the 'load' side of the FCU. Without Flex Outlet. Coloumb Screwfix Select. Discussion in 'Electricians' Talk' started by Mole80, May 13, 2023. If you wish to take more sockets, then you spur first to a fused connection unit (FCU) then on to the further sockets, you can have as many as you like down stream of the FCU but of course. 89Inc Vat. had the same with a heated towel rail fed from unswitched FCU bout 1 metre from shower head ,also a socket in a cupboard to charge up the electric toothbrush. FlyByNight, Jun 29, 2021. Home Forums > Screwfix Community Forum > Electricians' Talk > FCU/Socket Combination. KC DIY, Jun 24, 2021. Bazza-spark, Sep 15, 2023. Also from the junction box comes a short spur with a fused box. I assumed (maybe incorrectly) that what was required above would have been fed off the FCU load as is the cooker hood, so when the FCU switch would be off it would in turn also isolate these new sockets. com. Home Forums > Screwfix Community Forum > Electricians' Talk > Spur from ring main to socket and fcu. Credit Human CD changes: 6-11 month 5. Buy MK FCU Switches & Sockets at Screwfix. 1m length) from wall down to the joists then clipped around. FREE next day delivery available, free collection in 1 minute. Click to expand. Would still need a cooker fcu for isolation in the kitchen though. Pay your way. UK call centre ready for your call 24/7. Sign up to receive exclusive offers, vouchers and deals. As you have spured from the socket in 4. The load is a couple of rack mounted servers, so low current draw on the fcu. Terminals accept 2 x 1. Pay your way. I’ve also had the top cover trimmed down so it can ‘easily’ be removed (2 screws) if. g. Screwfix customers rate this product 4. 2. I would like to add one more single socket (LAP) to the FCU in my kitchen. Satisfied no power, then remove lid on alarm panel. Flex Outlet. Actually they are all correctly called fused connection units (FCUs). richc1234 Member. Which is the correct way to wire kitchen under cabinet lights? a) From the lighting circuit, if so does it need to be independently fused as they're in the kitchen? b) From the kitchen ring main, with an switched FCU spurred on the wall next to a socket? thanks in advance! JP. Supplied with Replaceable 13A Fuse. Flex Outlet. 84 Inc Vat. We provide deposit accounts, loans, credit cards, mortgage, refinancing options, and much more!Credit Human (easy membership) has substantially increased the rate on its 12-17 month CD and 12-month Liquid CD to rate-leading levels. com. Apple Pay accepted in store. Teki said: ↑. Need Help. FREE next day delivery available, free collection in 1 minute. com. Delivery 7 days a week. 5x10 — $65 / year. Without Flex Outlet. Terminal Capacity. Trips at 30mA. KIAB, Feb 6, 2020. Pay your way. Hundreds of stores nationwide. . Order MK Metal-Clad Plus 13A Switched Metal Clad Fused Spur & Flex Outlet with White Inserts at Screwfix. The most practical way IMHO is to install a single socket in an adjacent base unit so you can plug in the hob ignition. From the incredible Screwfix range of Home & Storage products, Kitchen Designs, Lighting, Paint & Varnish, Painting Accessories. Screwfix Select 1. Order online at Screwfix. Apple Pay accepted in store. Delivery 7 days a weekOrder online at Screwfix. Buy FCU Fused Spurs at Screwfix. Free returns. 5mm T&E in 20mm conduit (1. Buy Screwed FCU Switches & Sockets at Screwfix. FCU: Switches & Sockets Profile Type: Raised Rounded: Terminal Capacity: Terminals accept 3 x 2. . Break into the ring and connect a 13amp fcu. I therefore understood that it was still classed as within zone 2 because it was easily accessible (I have a feeling I may be wrong though from your comments). Join today and become part of the EFCU family. In which case the "fused spur," the fused flex, the fused cable, the fused load, whatever you call it, is functionally part of the accessory. Terminals accept 3 x 2. com. Posts 3, 4, 5, 10, & 16 are wrong. My question is, without taking it apart again what's the best way to seal the FCU housing to the conduit female accessory, and also the conduit to the female accessory. With RCD. PayPal accepted online. Screwfix: Thousands of products at trade prices | FREE delivery available 7 days a week | FREE click & collect in as little as a minute | Hundreds of storesTickets are now sold out for Hozier ’s May 21, 2024, performance at the Empower FCU Amphitheater in Syracuse. 30mA Active RCD. 5 or 2. spinlondon, Jan 11, 2019. 6amp breaker for the lights and a 16amp breaker for the couple. Make transfers and loan payments, apply for a loan, get account balances, view and print check copies, print statements, receive email notifications on account balances and so much more!Office Locator. I don't like the one linked to above - cheap maybe, but the cost of a J804 is not bank balance breaking. Screwfix Community Forum. With RCD. Without RCD. The UK’s leading retailer of trade tools and hardware. SF do one, so use a 4 way plate and three switches fed from a single fuse. Buy online & collect in hundreds of stores in as little as 1 minute! 30 day money back guarantee. 60 days free credit available. Many. This is perfectly OK, according to the regs. com. PayPal accepted online. Sigh. Alaska USA Federal Credit Union, founded in 1948, is a member-owned, not-for-profit cooperative, with a full range of financial services, including checking and savings accounts, consumer loans, real estate loans, mortgage loans, credit cards, business services and personal insurance. Screwfix Community Forum. Sign in / Register. Yes of course there is. Wellwisher said: ↑. Visit from any device — desktop, mobile, or tablet. You therefore need an RCBO. PayPal accepted online. Screwfix customers rate this product 4. Requires 35mm Back Box. Assemble with other products into a modular front plate to create a grid. Apple Pay accepted in store. Field Offices handle scheduled interviews on other applications. load. 9A so both boiler and pump will happily coexist on the same fcu. I can connect. Most integrated dishwashers have a recess at the base so the cable, infeed and waste pipe can be sat directly behind it at floor level and passed through the decor panel/service void into the cabinet socket/plumbing. 5mm² overload ? Mr. Deleted member 11267, Apr 23, 2018. Screwfix customers rate this product 4. the FCU is using the lighting circuit for the power. 5mm 3 core (L,N,E) ho7rnf rubber cable. Just run a twin and earth from the supply side of the existing fcu to the new ones supply side ,and connect both lights to its load side. Buy Fixings & Fastenings at Screwfix. com. Option 2. Free next day delivery available. Transfer between multiple deposit accounts & pay loans. The cable or flex attached to the gas fire is purely to supply the ignition. Terminals accept 3 x 2. as per the green lines on the diagram. com. It's exactly the same with the hood. For joining non-pressure pipes of differing outer diameters and materials. Terminals accept 3 x 2. However, I'm baffled by the existing rose's wiring. With online banking services from AERO Federal Credit Union, it’s never been easier—or safer—to manage your money online. Or under the bath, with a panel fitted that requires a tool (screwdriver) to remove panel (say for a shower pump/whirlpool bath)Bazza-spark Screwfix Select. I've heard. Screwfix Community Forum. Risteard Screwfix Select. If you are using an auxiliary aid or a screen reader and need assistance please dial 711 to be connected to a Member One representative, or call us direct at 800. Safety is the most important thing, and Screwfiz is making it easier than ever with 10% off DeWalt safety boots, and clothing. 1. Option 1. Coloumb Screwfix Select. With Flex Outlet. 4/5. there is absolutely no point in having a CU in the outbuilding. I have 3 cables coming through the ceiling to the existing pendant light. Discussion in ' Electricians' Talk ' started by DoItYoung, Feb 9, 2021 . The supplied switch (from Screwfix) doesn't have a wiring diagram. Also connect the feed to a switched FCU with a 3 or 5 amp fuse in it. They are available in a variety of current ratings (eg 16A, 32, etc). Delivery 7 days a week. Screwed Faceplate. The easiest way I can see to do this (without extending the boiler load cable, making additional hole and moving the FCU due to cable length) is to run an additional cable from the supply side of the FCU to the socket above through the. Download account information into Quicken. See pic for context. I have moved into a new house and have had an electrician put a light and socket in the loft for a shower pump. Can I tell him he`s talking c**p or not. For Appliance Protection Circuits. Bazza, Aug 30, 2020 #9. continuing in 2. 2. Titan TTB776VAC 1400W 30Ltr Wet & Dry Vacuum 220-240V (665KH) (101) compare. 2. 0mm cable you have fulfilled all the requirements of the regulations as long as it is okay for volt drop and you have used water-proof glands (CW type). To die?to sleep, No more; and by a sleep to say we end The heart-ache and the thousand remarks That flesh is heir to: 'tis a consummationHome Forums > Screwfix Community Forum > Electricians' Talk > Boiler and controller fcu Discussion in ' Electricians' Talk ' started by mrppp , Oct 11, 2016 . With Flex Outlet. Bazza Screwfix Select. I think one of the single I currently have though is 47mm, to allow space for the thicker cooker cables. Requires 35mm Back Box. Call us at 512. So total 2250 watts. After taking a look it appears that the existing outdoor socket is a spur itself, it is fed from an internal single socket (let’s call this the washing machine socket), which is fed by an internal FCU. Delivery. 2 x 4. 89Inc Vat. Terminals accept 3 x 2. 433. The light switch, again, like the socket, had a FCU installed just before the switch. 3. Order MK IP66 13A Weatherproof Outdoor Switched Fused Spur & Flex Outlet at Screwfix. This is perfectly OK, according to the regs. And as in te original query - a plug on a cooker hood. Buy online & collect in hundreds of stores in as little as 1 minute! Thousands of products. Raised Square. 30mA Active RCD. there’s no need. Order MK Logic Plus 13A Switched Fused Spur & Flex Outlet White at Screwfix. Here are some of the 600+ companies offering AMOCO at work as a benefit to their employees! Offer AMOCO @Work. Standard BS 13A 3 pin plugs can be used in. 3. The most practical way IMHO is to install a single socket in an adjacent base unit so you can plug in the hob ignition. Buy 45 A Fused Spurs at Screwfix. from a ring circuit it is ok to feed from the ring to the. Screwfix customers rate this product 4. Would it be ok to replace a single socket on ring main with an FCU to run a fridge? jimany, Nov 24, 2023 at 9:02 AM #1 All of the lines and rectangles in RED are the existing 2. Now imagine a ring with 8 sockets on it, and 9 spurs, some or all of which are wired in with junction boxes. Ind spark, Sep 15, 2023. 1. Curiousity about one thing has led me to find something else. Was to see if any one in the forum could see a problem. I'd like something as neat and compact as possible, so I'd been hoping to find a 2 gang external enclosure that contains both a socket and an FCU. Order online at Screwfix.